448D

Aluminium built-in louvre to match noise-reducing 448 louvres.

Airflow calculation

Specifications

Technical data

Maximum height (mm) 4000
Maximum width (mm) 4000
Installation depth (mm) 82
Blade height (mm) 153
Blade width (mm) 97
Maximum area (m²) 8.12
Airflow class 4
CD coefficient 0.139
CE coefficient 0.139
K-factor exhaust 51.8
Visual free passage in % 65
Physical free passage in % 33
Blade number used L.150DAD.01
Type of building Apartment; Residential
Type of concept Project
Burglar-proofing No
Standard mesh type MAZ3046

Airflow calculation

Specifications based on your calculation

Air movement
kg/m³
m
m²
dB(A)
dB(A)

In measurements, the actual throughput of a grille may differ from the theoretically calculated value. For grilles with fewer than 6 louvers, it is therefore advisable to specify a grille larger than calculated, or to request tailored advice.

Result